NSN 4120-01-581-0399
Part Details | AIR CONDITIONER
4120-01-581-0399 A self-contained unit designed to perform the functions of cooling, circulating, filtering, dehumidifying or otherwise processing of air. It may also be equipped to perform the additional functions of heating or humidifying. It may be the air cycle type used in aircraft or the vapor cycle type applicable to ground or aerospace equipment. Excludes ENVIRONMENTAL CONTROL UNIT, PERSONNEL, SELF-CONTAINED.
Alternate Parts: GS1H83ZAANWY011, 4120-01-581-0399, 01-581-0399, 4120015810399, 015810399
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | JAN 04, 2010 | 01-581-0399 | 06486 ( AIR CONDITIONER ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4120-01-581-0399
Part Number | Cage Code | Manufacturer |
---|---|---|
GS1H83ZAANWY011 | 0WJE1 | HDT EXPEDITIONARY SYSTEMS, INC. |
Technical Data | NSN 4120-01-581-0399
Characteristic | Specifications |
---|---|
CAPACITY RATING | 1.5 TONS NOMINAL |
CABINET MATERIAL | ALUMINUM |
SURFACE TREATMENT | PAINT |
CONDENSER COOLING TYPE | AIR |
VOLTAGE RATING | 208.0 VOLTS NOMINAL |
FREQUENCY RATING | 60.0 HERTZ NOMINAL |
COOLING CAPACITY IN BTU PER HOUR | 15000.0 MINIMUM AND 18000.0 MAXIMUM |
HEATING CAPACITY IN BTU PER HOUR | 7000.0 MINIMUM AND 14000.0 MAXIMUM |
OVERALL LENGTH | 28.250 INCHES NOMINAL |
OVERALL WIDTH | 30.000 INCHES NOMINAL |
WEIGHT | 228.000 POUNDS NOMINAL |
SPECIAL FEATURES | REFRIGERANT IS R-407C;OPERATES IN 2 COOLING MODES VIA SWITCH-HIGH COOL AT 18000 BTU AND LOW COOL AT 15000 BTU;OPERATES IN 2 HEATING MODES VIA SWITCH-HIGH HEAT AT 14000 BTU AND LOW HEAT AT 7000 BTU;CANVAS COVER INCLUDED FOR CONDENSER;LIQUID SIGHT GLASS VISIBLE FROM OUTSIDE OF THE ENCLOSURE SO REFRIGERANT LEVEL CAN BE DETERMINED WITHOUT OPENING THE ECU;ACCESS PORTS FOR READING SYSTEM PRESSURES AND REFRIGERATION CHARGING LOCATED OUTSIDE OF ENCLOSURE;FOUR HANDLES PROVIDED FOR LIFTING;HOUR METER PROVIDED FOR PREVENTIVE MAINTENANCE PLANNING;EASILY ACCESSIBLE CIRCUIT BREAKERS FOR POWER AND CONTROL VOLTAGE;PHASE MONITOR PROVIDED TO PREVENT DAMAGE;FRONT AND SIDE POWER HOOK UP POINTS |
PART NAME ASSIGNED BY CONTROLLING AGENCY | 18K-9K ENVIRONMENTAL CONTROL UNIT (ECU) |