NSN 4320-01-312-0309
Part Details | ROTARY PUMP UNIT
4320-01-312-0309 An assembled unit consisting of a commonly mounted rotary pump(s), prime mover(s), and the necessary components to provide for a complete operation.
Alternate Parts: 9493M91P01, 9493M91, H4724D, 4320-01-312-0309, 01-312-0309, 4320013120309, 013120309
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 43 | DEC 08, 1989 | 01-312-0309 | 18181 ( PUMP UNIT, ROTARY ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4320-01-312-0309
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 9493M91P01 | 07482 | GENERAL ELECTRIC COMPANYDBA GE |
| 9493M91 | 07482 | GENERAL ELECTRIC COMPANYDBA GE |
| H4724D | 63097 | VIKING PUMP INC. |
Technical Data | NSN 4320-01-312-0309
| Characteristic | Specifications |
|---|---|
| MAXIMUM DISCHARGE FLOW RATE | 10.0 GALLONS PER MINUTE |
| DISCHARGE PRESSURE | 100.0 POUNDS PER SQUARE INCH GAGE |
| OPERATING SPEED AT RATED CAPACITY | 1200.0 REVOLUTIONS PER MINUTE |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| PUMPING ELEMENT OPERATING POSITION | HORIZONTAL |
| ROTARY PUMP DESIGN | GEAR |
| OPERATION RELATIONSHIP DESIGN | SIMULTANEOUS |
| PUMP QUANTITY | 1 |
| INTAKE CONNECTION QUANTITY | 1 |
| INTAKE CONNECTION TYPE | THREADED INTERNAL |
| INTAKE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR | 1.500-11-1 TO 2 NPT |
| DISCHARGE CONNECTION QUANTITY | 1 |
| DISCHARGE CONNECTION TYPE | THREADED INTERNAL |
| DISCHARGE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR | 1.500-11-1 TO 2 NPT |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| PRIME MOVER COOLING MEDIUM | AIR |
| PRIME MOVER QUANTITY | 1 |
| PRIME MOVER POWER RATING | 1.5 HORSEPOWER |
| CURRENT TYPE | AC |
| VOLTAGE IN VOLTS | B230.0$$B460.0 |
| FREQUENCY IN HERTZ | 60.0 |
| PHASE | THREE |
| CURRENT RATING IN AMPS | B4.9$$B2.5 |
| INCLOSURE TYPE | FULLY INCLOSED |
| COOLING METHOD | BLOWER COOLED |
| MOUNTING TYPE | FRAME |