NSN 4810-00-328-5418
Part Details | SOLENOID VALVE
4810-00-328-5418 A valve having two or more ports with valve stem or pilot needle in a normally open or closed position. It is specifically designed to stop or start or change the flow of fluid by means of the magnetic action of an electric coil on a moveable core or plunger. The valve may be equipped with a manual opening or closing device. For items with three or more ports that utilize a reciprocating slide with recess areas which mate with ports in an integral or replaceable ported sleeve, see VALVE (1), LINEAR, DIRECTIONAL CONTROL. It may be inline or cartridge (manifold) design. Excludes VALVE (1), BUTTERFLY.
Alternate Parts: 7602576002, 7602576-002, B11DK 120012060, B11DK 1200-120-60, B1DA120012060, B1DA1-200-120-60, 4810-00-328-5418, 00-328-5418, 4810003285418, 003285418
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
48 | DEC 09, 1973 | 00-328-5418 | 10998 ( VALVE, SOLENOID ) |
REFERENCE DRAWINGS & PICTURES
STRAIGHT THRU
Cross Reference | NSN 4810-00-328-5418
Part Number | Cage Code | Manufacturer |
---|---|---|
7602576-002 | 93322 | GE AVIATION SYSTEMS LLCDBA GE AVIATION |
B11DK 1200-120-60 | 81978 | PARKER-HANNIFIN CORPORATIONDBA FLUID CONTROLS DIVISION |
B1DA1-200-120-60 | 81978 | PARKER-HANNIFIN CORPORATIONDBA FLUID CONTROLS DIVISION |
Technical Data | NSN 4810-00-328-5418
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | STRAIGHT THRU |
FLOW CONTROL DEVICE | DISK |
VALVE OPERATION METHOD | SOLENOID |
VOLTAGE IN VOLTS AND CURRENT TYPE | 120.0 AC |
FREQUENCY IN HERTZ | 60.0 |
PHASE | SINGLE |
FLOW CONTROL DEVICE NORMAL OPERATION POSITION | CLOSED |
APERTURE DIAMETER | 0.047 INCHES NOMINAL |
MOUNTING POSITION | VERTICAL |
SPECIAL FEATURES | BURST PRESSURE 10,000 PSI |