NSN 4820-00-407-8427
Part Details | CALIBRATED FLOW VALVE
4820-00-407-8427 A valve specifically designed to automatically maintain a predetermined discharge flow rate which may be adjustable within a specific range. It is designed to be used with various fluids and may be preset and/or adjustable. It may be in-line or cartridge (manifold) design. Excludes VALVE, REGULATING, FEED WATER; VALVE, REGULATING, FLUID PRESSURE; VALVE, REGULATING, FUEL OIL; VALVE, REGULATING, OIL PRESSURE, AUTOMATIC PILOT; VAVLE, REGULATING, TEMPERATURE; VALVE, ANGLE; and VALVE, GLOBE.
Alternate Parts: 194T1072, 194T10-7-2, 194TC1107.2, 194TC1-10-7.2, 194T1072, 194T10-7-2, 194TC1107.2, 194TC1-10-7.2, 4820-00-407-8427, 00-407-8427, 4820004078427, 004078427
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 48 | JAN 18, 1972 | 00-407-8427 | 33212 ( VALVE, CALIBRATED FLOW ) |
REFERENCE DRAWINGS & PICTURES
STRAIGHT THRU
GASKET SEAL
GASKET SEAL
GASKET SEAL
GASKET SEAL
Cross Reference | NSN 4820-00-407-8427
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 194T10-7-2 | 82271 | PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC CARTRIDGE SYSTEMS DIV |
| 194TC1-10-7.2 | 82271 | PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC CARTRIDGE SYSTEMS DIV |
| 194T10-7-2 | 09990 | PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC VALVE DIV |
| 194TC1-10-7.2 | 09990 | PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC VALVE DIV |
Technical Data | NSN 4820-00-407-8427
| Characteristic | Specifications |
|---|---|
| BODY MATERIAL | STEEL |
| VALVE DISCHARGE FLOW RATE | 7.2 GALLONS PER MINUTE |
| FLOW CONTROL DEVICE MATERIAL | STEEL, CORROSION RESISTING |
| END CONNECTION QUANTITY | 2 |
| FIRST END CONNECTION TYPE | THREADED INTERNAL BOSS |
| FIRST END STYLE DESIGNATOR | GASKET SEAL |
| FIRST END THREAD SIZE AND SERIES/TYPE DESIGNATOR | 7 TO 8-14 UNF |
| FIRST END THREAD CLASS | 2B |
| FIRST END THREAD DIRECTION | RIGHT-HAND |
| SECOND END RELATIONSHIP WITH FIRST END | IDENTICAL |
| BODY STYLE | STRAIGHT THRU |
| MEDIA FOR WHICH DESIGNED | HYDRAULIC OIL |
| REGULATION TYPE | AUTOMATIC SINGLE STAGE |