NSN 4820-00-928-2579
Part Details | FLUID PRESSURE REGULATING VALVE
4820-00-928-2579 A valve designed to automatically maintain within close limits a predetermined outlet pressure which may be adjustable within a specified range regardless of the higher fluctuating or constant inlet pressure. It is designed for use with compressed gas(es) and various liquids and may include gauges. It may be inline or cartridge (manifold) design. Excludes REGULATOR, PRESSURE, MEDICAL GAS ADMINISTRATION APPARATUS; REGULATOR, OXYGEN, BAROMETRIC CONTINUOUS FLOW; REGULATOR, OXYGEN DEMAND; REGULATOR, OXYGEN DILUTER DEMAND; and valve(1), fluid pressure regulating, aircraft.
Alternate Parts: 14796, 14796, 4820-00-928-2579, 00-928-2579, 4820009282579, 009282579
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 48 | APR 24, 1968 | 00-928-2579 | 27565 ( VALVE, REGULATING, FLUID PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
STRAIGHT THRU
SWIVEL NUT, FLARE
SWIVEL NUT, FLARE
SWIVEL NUT, FLARE
SWIVEL NUT, FLARE
Cross Reference | NSN 4820-00-928-2579
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 14796 | 06023 | REGO COA MARMON GROUP CO |
| 14796 | 03670 | TYCO FIRE PRODUCTS LPDBA TYCO FIRE PROTECTION PRODUCTS |
Technical Data | NSN 4820-00-928-2579
| Characteristic | Specifications |
|---|---|
| BODY MATERIAL | ALUMINUM |
| FILTER | NOT INCLUDED |
| FLOW CONTROL DEVICE | STEM AND INTEGRAL DISK |
| OUTSIDE SURFACE TREATMENT | CHROMIUM |
| END CONNECTION QUANTITY | 2 |
| FIRST END CONNECTION TYPE | THREADED INTERNAL PIPE |
| FIRST END STYLE DESIGNATOR | 1 SWIVEL NUT, FLARE |
| FIRST END THREAD SIZE AND SERIES/TYPE DESIGNATOR | 1 TO 8-18 NPT |
| FIRST END THREAD DIRECTION | RIGHT-HAND |
| SECOND END RELATIONSHIP WITH FIRST END | IDENTICAL |
| BODY STYLE | STRAIGHT THRU |
| MEDIA FOR WHICH DESIGNED | NITROGEN, LIQUID |
| REGULATION TYPE | 1ST STAGE MANUAL, 2ND STAGE AUTOMATIC |
| MANUAL CONTROL METHOD | SCREW |
| VALVE LOADING METHOD | SPRING |