NSN 4820-01-523-4090

Part Details | OXYGEN SYSTEM PRESSURE REGULATING VALVE

4820-01-523-4090 A valve used to automatically maintain within close limits a predetermined pressure within an oxygen system regardless of the higher fluctuating or constant inlet pressure. The excess pressure is bypassed to the accumulator or reservoir in lieu of passing through the entire system. It is specifically designed and/or cleaned for oxygen systems. Excludes VALVE, REGULATING, SYSTEM PRESSURE; VALVE REGULATING, FLUID PRESSURE AND VALVE, CALIBRATED FLOW.

Alternate Parts: 106730030, 10673-0030, FRM2 12 0T30PSI, FRM-2 1/2 0T30PSI, 106730030CP, 10673-0030CP, FRM2 12IN 0T30PSICP, FRM-2 1/2IN 0T30PSICP, 106730030, 10673-0030, 4820-01-523-4090, 01-523-4090, 4820015234090, 015234090

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
48SEP 01, 200401-523-409037940 ( VALVE, REGULATING, OXYGEN SYSTEM PRESSURE )
REFERENCE DRAWINGS & PICTURES

STRAIGHT THRU

GASKET SEAL

GASKET SEAL

GASKET SEAL

GASKET SEAL

Cross Reference | NSN 4820-01-523-4090
Part Number Cage Code Manufacturer
10673-003071342IMI CASH VALVE INC
FRM-2 1/2 0T30PSI71342IMI CASH VALVE INC
10673-0030CP03950NAVAL INVENTORY CONTROL POINTMECHANICSBURG
FRM-2 1/2IN 0T30PSICP03950NAVAL INVENTORY CONTROL POINTMECHANICSBURG
10673-00301X5W8PENTAIR VALVES & CONTROLS US LPDBA MARINE PRODUCT TEAM
Technical Data | NSN 4820-01-523-4090
Characteristic Specifications
BODY MATERIAL BRASS
SPECIAL FEATURESPRESSURE RANGE IS SET BETWEEN 0 TO 30 PSI; REQUIRES SPECIAL CLEANING AND PACKAGING FOR OXYGEN SERVICE
CRITICALITY CODE JUSTIFICATIONFEAT
PART NAME ASSIGNED BY CONTROLLING AGENCYBACK PRESSURE VALVE, SIDE IN, SIDE OUT; CRYOGENIC
FLOW CONTROL DEVICE DIAPHRAGM
END CONNECTION QUANTITY2
FIRST END CONNECTION TYPE THREADED INTERNAL PIPE
FIRST END STYLE DESIGNATOR GASKET SEAL
FIRST END THREAD SIZE AND SERIES/TYPE DESIGNATOR0.500 NPT
FIRST END THREAD DIRECTION RIGHT-HAND
SECOND END RELATIONSHIP WITH FIRST END IDENTICAL
BODY STYLE STRAIGHT THRU
FACE TO FACE DISTANCE2.560 INCHES NOMINAL
MEDIA FOR WHICH DESIGNED OXYGEN, GASEOUS
REGULATION TYPE AUTOMATIC SINGLE STAGE
VALVE LOADING METHOD SPRING