NSN 5905-00-001-3031
Part Details | COMPOSITION FIXED RESISTOR
5905-00-001-3031 A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of a mixture of carbon, an insulating material, and suitable binders, either molded together or applied as a thin layer of conducting material on an insulated form. The opposition to the flow of current is an inherent property of the materials used and is manifest by the heat dissipation in the item itself. See also ATTENUATOR, FIXED; RESISTOR, FIXED, FILM; and RESISTOR, THERMAL. Excludes SUPPRESSOR, IGNITION INTERFERENCE.
Alternate Parts: OH1831, 06921835, 0692-1835, 81319079, 813190-79, RC42GF183J, RC42BF183K, RCR42G183KS, RCR42G183JS, MILR390085, MIL-R-39008/5, 28001147P119, 280-01147P119, 5905-00-001-3031, 00-001-3031, 5905000013031, 000013031
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | SEP 24, 1972 | 00-001-3031 | 00126 ( RESISTOR, FIXED, COMPOSITION ) |
REFERENCE DRAWINGS & PICTURES
AXIAL TERMINAL EACH END
Cross Reference | NSN 5905-00-001-3031
Part Number | Cage Code | Manufacturer |
---|---|---|
OH1831 | 44655 | HEICO OHMITE, L.L.C.DBA OHMITE MANUFACTURING |
0692-1835 | 28480 | HEWLETT-PACKARD COMPANYDBA HP |
813190-79 | 56232 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN |
RC42GF183J | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
RC42BF183K | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
RCR42G183KS | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
RCR42G183JS | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-R-39008/5 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
280-01147P119 | 49956 | RAYTHEON COMPANYDBA RAYTHEON |
Technical Data | NSN 5905-00-001-3031
Characteristic | Specifications |
---|---|
ELECTRICAL RESISTANCE | 18.000 KILOHMS |
RESISTANCE TOLERANCE IN PERCENT | M5.000/P5.000 |
POWER DISSIPATION RATING IN WATTS | 2.000 FREE AIR |
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0 |
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 130.0 |
INCLOSURE METHOD | ENCAPSULATED |
STYLE DESIGNATOR | 4 AXIAL TERMINAL EACH END |
BODY DIAMETER | 0.318 INCHES NOMINAL |
BODY LENGTH | 0.688 INCHES NOMINAL |
TERMINAL TYPE | WIRE LEAD |
RELIABILITY INDICATOR | ESTABLISHED |
RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.001 |
TERMINAL LENGTH | 1.500 INCHES NOMINAL |
CUBIC MEASURE | 0.070 CUBIC INCHES |
TEST DATA DOCUMENT | 81349-MIL-R-39008 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 81349-MIL-R-39008 TO 5 GOVERNMENT SPECIFICATION |
UNPACKAGED UNIT WEIGHT | 3.000 GRAMS |