NSN 5910-00-189-3579
Part Details | ELECTROLYTIC FIXED CAPACITOR
5910-00-189-3579 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.
Alternate Parts: 696124223, 696124-223, ECH223K35AS, 83243223H6, 83243-223H6, 906071562, 9060715-62, MILC390031, MILC39003-1, CSR13G223KM, M39003013046, M39003/01-3046, M39003012326, M39003-01-2326, M39003010427, M39003-01-0427, M3900012327, M3900/01-2327, 1849084140, 184-9084-140, CS211862, CS2118-62, 696124223, 696124-223, 906071562, 9060715-62, 150D223X9035A0, 5910-00-189-3579, 00-189-3579, 5910001893579, 001893579
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | MAR 11, 1973 | 00-189-3579 | 00008 ( CAPACITOR, FIXED, ELECTROLYTIC ) |
REFERENCE DRAWINGS & PICTURES
W/O MTG FACILITIES, AXIAL TERMINALS
ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
Cross Reference | NSN 5910-00-189-3579
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 696124-223 | 12436 | BAE SYSTEMS INFORMATION ANDELECTRONIC SYSTEMS INTEGRATION INC. |
| ECH223K35AS | 99251 | CARLETON LIFE SUPPORT SYSTEMS INC.DBA COBHAM MISSION SYSTEM |
| 83243-223H6 | 15786 | GENERAL INSTRUMENT CORPDALMO VICTOR DIV |
| 9060715-62 | 99167 | HAMILTON SUNDSTRAND CORPORATION |
| MILC39003-1 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| CSR13G223KM | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| M39003/01-3046 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| M39003-01-2326 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| M39003-01-0427 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| M3900/01-2327 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| 184-9084-140 | 13499 | ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS |
| CS2118-62 | 26769 | SPRAGUE PALM BEACH INCA VISHAY/SPRAGUE CO |
| 696124-223 | 14100 | STROMBERG-CARLSON CORPA PLESSEY TELECOMMUNICATIONS CO |
| 9060715-62 | 83843 | SUNDSTRAND CORPELECTRIC POWER SYSTEMS DIV |
| 150D223X9035A0 | 89307 | TELEDYNE SPRAGUE ENGINEERINGTELEDYNE INDUSTRIES INC SUB OF |
Technical Data | NSN 5910-00-189-3579
| Characteristic | Specifications |
|---|---|
| CAPACITANCE VALUE PER SECTION | 22000.000 PICOFARADS SINGLE SECTION |
| TOLERANCE RANGE PER SECTION | -10.00 TO +10.00 PERCENT SINGLE SECTION |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 50.0 DC SINGLE SECTION |
| NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALS |
| BODY DIAMETER | 0.135 INCHES NOMINAL |
| BODY LENGTH | 0.286 INCHES NOMINAL |
| SCHEMATIC DIAGRAM DESIGNATOR | ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL |
| TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| TERMINAL LENGTH | 1.500 INCHES NOMINAL |
| TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
| CASE MATERIAL | METAL |
| CASE INSULATION MATERIAL | PLASTIC |
| CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
| DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 2.0000 |
| DC LEAKAGE AT REFERENCE TEMP | 0.500 MICROAMPERES |
| ELECTRICAL POLARIZATION | POLARIZED |
| RELIABILITY INDICATOR | ESTABLISHED |
| RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.0010 |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| TEST DATA DOCUMENT | 81349-MIL-C-39003 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| SPECIFICATION/STANDARD DATA | 81349-MIL-C-39003 TO 1 GOVERNMENT SPECIFICATION |
| MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | N-3 |
| ANODE TYPE | SOLID |
| DC LEAKAGE AT MAXIMUM OPERATING TEMP | 5.0 MICROAMPERES |