NSN 5910-00-221-8119

Part Details | ELECTROLYTIC FIXED CAPACITOR

5910-00-221-8119 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Alternate Parts: CE51C301G, MILC628, MILC62-8, CE56C331H, CE56C3016, 5910-00-221-8119, 00-221-8119, 5910002218119, 002218119

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUN 25, 196900-221-811900008 ( CAPACITOR, FIXED, ELECTROLYTIC )
REFERENCE DRAWINGS & PICTURES

W/O MTG FACILITIES, TERMINAL(S) ON ONE END

ELECTRODE(S) GROUNDED TO CASE

Cross Reference | NSN 5910-00-221-8119
Part Number Cage Code Manufacturer
CE51C301G00656AEROVOX CORP.
MILC62-881349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
CE56C331H81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
CE56C301681349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
Technical Data | NSN 5910-00-221-8119
Characteristic Specifications
CAPACITANCE VALUE PER SECTION330.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION-10.00 TO +75.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION100.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-40.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE W/O MTG FACILITIES, TERMINAL(S) ON ONE END
BODY DIAMETER1.562 INCHES NOMINAL
BODY LENGTH2.562 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR ELECTRODE(S) GROUNDED TO CASE
TERMINAL TYPE AND QUANTITY4 STANDARD TUBE BASE
CASE MATERIAL METAL
CASE INSULATION MATERIAL PLASTIC
CAPACITIVE ELECTRODE MATERIAL ALUMINUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT15.0000
DC LEAKAGE AT REFERENCE TEMP271.000 MICROAMPERES
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR NOT ESTABLISHED
TEST DATA DOCUMENT81349-MIL-C-62 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
SPECIFICATION/STANDARD DATA81349-MIL-C-62 TO 8 GOVERNMENT SPECIFICATION
TERMINAL SURFACE TREATMENT NICKEL
ANODE TYPE PLAIN FOIL
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS27.0