NSN 5910-00-226-7144

Part Details | MICA DIELECTRIC FIXED CAPACITOR

5910-00-226-7144 A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Alternate Parts: DM16F162G0100WV4CR, DM16E162G0100WV4, DM16162J, DM16-162J, DM16162G, DM16-162G, 930006158, 930-006-158, 930006258, 930-006-258, 5910-00-226-7144, 00-226-7144, 5910002267144, 002267144

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-226-714400005 ( CAPACITOR, FIXED, MICA DIELECTRIC )
REFERENCE DRAWINGS & PICTURES

W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE

NO COMMON OR GROUNDED ELECTRODE(S)

Cross Reference | NSN 5910-00-226-7144
Part Number Cage Code Manufacturer
DM16F162G0100WV4CR72136ELECTRO MOTIVE CORP SUBSIDIARY OFINTERNATIONAL ELECTRONICS CORP
DM16E162G0100WV472136ELECTRO MOTIVE CORP SUBSIDIARY OFINTERNATIONAL ELECTRONICS CORP
DM16-162J72136ELECTRO MOTIVE CORP SUBSIDIARY OFINTERNATIONAL ELECTRONICS CORP
DM16-162G72136ELECTRO MOTIVE CORP SUBSIDIARY OFINTERNATIONAL ELECTRONICS CORP
930-006-15888272MANIABARCO INC.
930-006-25889372ROCKWELL INTERNATIONAL CORPNORTH AMERICAN AIRCRAFT OPNS
Technical Data | NSN 5910-00-226-7144
Characteristic Specifications
CAPACITANCE VALUE PER SECTION1600.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION-2.00 TO +2.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION100.0 DC SINGLE SECTION
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS+0.0 TO +70.0 SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY LENGTH0.736 INCHES MAXIMUM
BODY WIDTH0.378 INCHES MAXIMUM
BODY HEIGHT0.220 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL LENGTH1.250 INCHES MINIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.469 INCHES MINIMUM AND 0.531 INCHES MAXIMUM
CASE MATERIAL PLASTIC
INSULATION RESISTANCE AT REFERENCE TEMP10000.0 MEGOHMS
RELIABILITY INDICATOR NOT ESTABLISHED