NSN 5910-00-232-2989

Part Details | MICA DIELECTRIC FIXED CAPACITOR

5910-00-232-2989 A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Alternate Parts: CD15FD(455)F03, D155F4550F0, DM15F4550F0500WV4CR, RDM15FD4550F03, 6792858000, 679-2858-000, TK15455PF501, 283067300, 283-0673-00, 5910-00-232-2989, 00-232-2989, 5910002322989, 002322989

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59OCT 28, 197000-232-298900005 ( CAPACITOR, FIXED, MICA DIELECTRIC )
REFERENCE DRAWINGS & PICTURES

W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE

NO COMMON OR GROUNDED ELECTRODE(S)

Cross Reference | NSN 5910-00-232-2989
Part Number Cage Code Manufacturer
CD15FD(455)F0393790CORNELL-DUBILIER ELECTRONICS
D155F4550F000853CORNELL-DUBILIER MARKETING, INC.
DM15F4550F0500WV4CR72136ELECTRO MOTIVE CORP SUBSIDIARY OFINTERNATIONAL ELECTRONICS CORP
RDM15FD4550F0361403MICONICS INDUSTRIESDIV OF BELL INDUSTRIES
679-2858-00013499ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS
TK15455PF50157582SUSCO ELECTRONICS INC
283-0673-0080009TEKTRONIX, INC.DBA TEKTRONIX
Technical Data | NSN 5910-00-232-2989
Characteristic Specifications
CAPACITANCE VALUE PER SECTION455.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION-1.00 TO +1.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION500.0 DC SINGLE SECTION
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS+0.0 TO +70.0 SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY LENGTH0.480 INCHES MAXIMUM
BODY WIDTH0.410 INCHES MAXIMUM
BODY HEIGHT0.230 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL LENGTH1.250 INCHES MINIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.203 INCHES MINIMUM AND 0.265 INCHES MAXIMUM
CASE MATERIAL PLASTIC
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
QUALITY FACTOR AT REFERENCE TEMP2000.0000
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL SURFACE TREATMENT SOLDER
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP20000.0 MEGOHMS