NSN 5910-00-617-4206
Part Details | CERAMIC DIELECTRIC FIXED CAPACITOR
5910-00-617-4206 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.
Alternate Parts: C2203594, C220359-4, GA51UUFPORM5PCT, GA5-1UUFPORM5PCT, SMB6507572, SMB650757-2, 5910-00-617-4206, 00-617-4206, 5910006174206, 006174206
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1963 | 00-617-4206 | 00007 ( CAPACITOR, FIXED, CERAMIC DIELECTRIC ) |
REFERENCE DRAWINGS & PICTURES
W/O MTG FACILITIES, AXIAL TERMINALS
NO COMMON OR GROUNDED ELECTRODE(S)
Cross Reference | NSN 5910-00-617-4206
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| C220359-4 | 06845 | RAYTHEON COMPANYDBA RAYTHEON |
| GA5-1UUFPORM5PCT | 78488 | STACKPOLE CORP THE |
| SMB650757-2 | 80063 | US ARMY COMMUNICATIONS &ELECTRONICS MATERIEL READINESS |
Technical Data | NSN 5910-00-617-4206
| Characteristic | Specifications |
|---|---|
| CAPACITANCE VALUE PER SECTION | 5.100 PICOFARADS SINGLE SECTION |
| TOLERANCE RANGE PER SECTION | -5.00 TO +5.00 PERCENT SINGLE SECTION |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 500.0 DC SINGLE SECTION |
| VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE | BCNM3.0 TO +3.0 WITHOUT VOLTAGE APPLIED |
| NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALS |
| BODY DIAMETER | 0.150 INCHES MINIMUM AND 0.170 INCHES MAXIMUM |
| BODY LENGTH | 0.330 INCHES MAXIMUM |
| SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| TERMINAL LENGTH | 1.380 INCHES MINIMUM AND 1.620 INCHES MAXIMUM |
| TERMINAL DIAMETER | 0.032 INCHES NOMINAL |
| CASE MATERIAL | PLASTIC |
| INSULATION RESISTANCE AT REFERENCE TEMP | 1000.0 MEGOHMS |
| DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 1.000 |
| POWER FACTOR AT REFERENCE TEMP IN PERCENT | 1.000 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TERMINAL SURFACE TREATMENT | SOLDER |