NSN 5910-00-760-7844
Part Details | CERAMIC DIELECTRIC FIXED CAPACITOR
5910-00-760-7844 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.
Alternate Parts: 562CZ5UBA101AF103Z, 19C233A2, 19040493, 190-40-493, 19040493, 190-40-493, 19C233A2, 5910-00-760-7844, 00-760-7844, 5910007607844, 007607844
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1960 | 00-760-7844 | 00007 ( CAPACITOR, FIXED, CERAMIC DIELECTRIC ) |
REFERENCE DRAWINGS & PICTURES
W/O MTG FACILITIES, RADIAL TERMINALS
NO COMMON OR GROUNDED ELECTRODE(S)
Cross Reference | NSN 5910-00-760-7844
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 562CZ5UBA101AF103Z | 60705 | CERA-MITE CORP |
| 19C233A2 | 60705 | CERA-MITE CORP |
| 190-40-493 | 25549 | LITTON SYSTEMS INCAMECOM DIV |
| 190-40-493 | 92755 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDBA LAND & SELF PROTECTION SYSTEM |
| 19C233A2 | 56289 | SPRAGUE ELECTRIC COWORLD HQS |
Technical Data | NSN 5910-00-760-7844
| Characteristic | Specifications |
|---|---|
| CAPACITANCE VALUE PER SECTION | 10000.000 PICOFARADS SINGLE SECTION |
| TOLERANCE RANGE PER SECTION | -20.00 TO +80.00 PERCENT SINGLE SECTION |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 100.0 DC SINGLE SECTION |
| VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE | C56.0 TO +22.0 WITH RATED VOLTAGE APPLIED |
| NONDERATED OPERATING TEMP | 10.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| BODY STYLE | W/O MTG FACILITIES, RADIAL TERMINALS |
| BODY DIAMETER | 0.350 INCHES MAXIMUM |
| BODY LENGTH | 0.125 INCHES MAXIMUM |
| SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| TERMINAL LENGTH | 1.250 INCHES MINIMUM |
| TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
| CASE MATERIAL | PLASTIC |
| INSULATION RESISTANCE AT REFERENCE TEMP | 7500.0 MEGOHMS |
| DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 3.0000 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TERMINAL SURFACE TREATMENT | SOLDER |