Part Details | CERAMIC DIELECTRIC FIXED CAPACITOR

5910-00-843-9902 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Alternate Parts: 362X5U152M, 362000X5U0152M, 362-000X5U0152M, 01600734, 0160-0734, 01600734, 0160-0734, 362X5U152M, 362000X5U0152M, 362-000-X5U0-152M, 362000 X5U 152M, 362-000 X5U 152M, 5910-00-843-9902, 00-843-9902, 5910008439902, 008439902

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196200-843-990200007 ( CAPACITOR, FIXED, CERAMIC DIELECTRIC )
REFERENCE DRAWINGS & PICTURES

W/THD BUSHING MTG, TERMINALS ON OPPOSITE END

FEEDTHROUGH

Cross Reference | NSN 5910-00-843-9902
Part Number Cage Code Manufacturer
362X5U152M72982ERIE SPECIALTY PRODUCTS INC
362-000X5U0152M72982ERIE SPECIALTY PRODUCTS INC
0160-073428480HEWLETT-PACKARD COMPANYDBA HP
0160-07341LQK8KEYSIGHT TECHNOLOGIES, INC.
362X5U152M59660TUSONIX, INC.
362-000-X5U0-152M59660TUSONIX, INC.
362-000 X5U 152M59660TUSONIX, INC.
Technical Data | NSN 5910-00-843-9902
Characteristic Specifications
CAPACITANCE VALUE PER SECTION1500.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION-20.00 TO +20.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION500.0 DC SINGLE SECTION
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGEBCNM56.0 TO +22.0 WITHOUT VOLTAGE APPLIED
NONDERATED OPERATING TEMP-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE W/THD BUSHING MTG, TERMINALS ON OPPOSITE END
WIDTH ACROSS FLATS0.312 INCHES NOMINAL
BODY LENGTH0.625 INCHES NOMINAL
BODY WIDTH0.625 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR FEEDTHROUGH
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL LENGTH1.312 INCHES NOMINAL
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE0.216 INCHES
POWER FACTOR AT REFERENCE TEMP IN PERCENT3.0000
RELIABILITY INDICATOR NOT ESTABLISHED