NSN 5910-00-890-4359

Part Details | CERAMIC DIELECTRIC FIXED CAPACITOR

5910-00-890-4359 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Alternate Parts: 636023, 6360-23, MINV002Z, MINV0-02Z, 21K861444, 5910-00-890-4359, 00-890-4359, 5910008904359, 008904359

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59APR 12, 196800-890-435900007 ( CAPACITOR, FIXED, CERAMIC DIELECTRIC )
REFERENCE DRAWINGS & PICTURES

W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE

NO COMMON OR GROUNDED ELECTRODE(S)

Cross Reference | NSN 5910-00-890-4359
Part Number Cage Code Manufacturer
6360-2380138KAY ELEMETRICS CORPORATION
MINV0-02Z09052SAFT AMERICA INC.DBA TRANSPORTATION DIVISION
21K86144401WR9STATE HEALTH SERVICES, TEXASDEPARTMENT OF
Technical Data | NSN 5910-00-890-4359
Characteristic Specifications
CAPACITANCE VALUE PER SECTION20000.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION-20.00 TO +100.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION75.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY LENGTH0.385 INCHES MAXIMUM
BODY WIDTH0.385 INCHES MAXIMUM
BODY HEIGHT0.080 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL LENGTH1.250 INCHES MINIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.185 INCHES MINIMUM AND 0.215 INCHES MAXIMUM
CASE MATERIAL PLASTIC
INSULATION RESISTANCE AT REFERENCE TEMP10000.0 MEGOHMS
POWER FACTOR AT REFERENCE TEMP IN PERCENT2.5000
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL SURFACE TREATMENT SOLDER