NSN 5910-00-890-9721

Part Details | ELECTROLYTIC FIXED CAPACITOR

5910-00-890-9721 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Alternate Parts: 13100033, 13-100033, 1112053, 1-112053, 691380017, 691380-017, 5910-00-890-9721, 00-890-9721, 5910008909721, 008909721

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59APR 10, 196800-890-972100008 ( CAPACITOR, FIXED, ELECTROLYTIC )
REFERENCE DRAWINGS & PICTURES

W/O MTG FACILITIES, AXIAL TERMINALS

NO COMMON OR GROUNDED ELECTRODE(S)

Cross Reference | NSN 5910-00-890-9721
Part Number Cage Code Manufacturer
13-10003374861CHARLES INDUSTRIES, LTD.DIV TELECOM/MARINE AND INDUSTRIAL
1-11205374861CHARLES INDUSTRIES, LTD.DIV TELECOM/MARINE AND INDUSTRIAL
691380-01706141L3 AVIATION PRODUCTS, INC.
Technical Data | NSN 5910-00-890-9721
Characteristic Specifications
CAPACITANCE VALUE PER SECTION0.270 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION-10.00 TO +10.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION100.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE W/O MTG FACILITIES, AXIAL TERMINALS
BODY DIAMETER0.400 INCHES NOMINAL
BODY LENGTH0.960 INCHES NOMINAL
BODY WIDTH0.531 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL LENGTH1.563 INCHES MINIMUM
TERMINAL DIAMETER0.025 INCHES NOMINAL
CASE MATERIAL PLASTIC
CAPACITIVE ELECTRODE MATERIAL ALUMINUM
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL SURFACE TREATMENT SOLDER