NSN 5910-00-900-0629

Part Details | ELECTROLYTIC FIXED CAPACITOR

5910-00-900-0629 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Alternate Parts: 13K943, 4410765006, 441-0765-006, MTP006, 5910-00-900-0629, 00-900-0629, 5910009000629, 009000629

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196000-900-062900008 ( CAPACITOR, FIXED, ELECTROLYTIC )
REFERENCE DRAWINGS & PICTURES

W/O MTG FACILITIES, AXIAL TERMINALS

ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL

Cross Reference | NSN 5910-00-900-0629
Part Number Cage Code Manufacturer
13K94356699BC COMPONENTS
441-0765-00694756BOEING COMPANY, THEDBA BOEING
MTP00637942YOSEMITE INVESTMENT INCDBA NORTH AMERICAN CAPACITOR CO
Technical Data | NSN 5910-00-900-0629
Characteristic Specifications
CAPACITANCE VALUE PER SECTION120.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION-20.00 TO +20.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION30.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-35.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE W/O MTG FACILITIES, AXIAL TERMINALS
BODY DIAMETER0.225 INCHES MAXIMUM
BODY LENGTH0.778 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL LENGTH1.500 INCHES MINIMUM
CASE MATERIAL METAL
CASE INSULATION MATERIAL PLASTIC
CAPACITIVE ELECTRODE MATERIAL TANTALUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT8.5000
DC LEAKAGE AT REFERENCE TEMP10.000 MICROAMPERES
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR NOT ESTABLISHED
TEST DATA DOCUMENT94756-441-0765 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
CRITICALITY CODE JUSTIFICATIONTEST
TERMINAL SURFACE TREATMENT SOLDER
DC LEAKAGE AT MAXIMUM OPERATING TEMP30.0 MILLIAMPERES