Part Details | ELECTROLYTIC FIXED CAPACITOR
5910-01-048-8757 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.
Alternate Parts: M39006098307, M39006-09-8307, MILC390069, MIL-C-39006/9, CLR65BH101KGM, 109604, 109604, 5910-01-048-8757, 01-048-8757, 5910010488757, 010488757
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | OCT 07, 1977 | 01-048-8757 | 00008 ( CAPACITOR, FIXED, ELECTROLYTIC ) |
REFERENCE DRAWINGS & PICTURES
W/O MTG FACILITIES, AXIAL TERMINALS
NO COMMON OR GROUNDED ELECTRODE(S)
Cross Reference | NSN 5910-01-048-8757
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| M39006-09-8307 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-C-39006/9 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| CLR65BH101KGM | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| 109604 | 04971 | RANTEC MICROWAVE SYSTEMS, INC.DBA RANTEC MICROWAVE ANTENNAS |
| 109604 | 60132 | RANTEC POWER SYSTEMS INC. |
Technical Data | NSN 5910-01-048-8757
| Characteristic | Specifications |
|---|---|
| CAPACITANCE VALUE PER SECTION | 100.000 MICROFARADS SINGLE SECTION |
| TOLERANCE RANGE PER SECTION | -10.00 TO +10.00 PERCENT SINGLE SECTION |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 30.0 DC SINGLE SECTION |
| NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALS |
| BODY DIAMETER | 0.406 INCHES NOMINAL |
| BODY LENGTH | 0.782 INCHES MINIMUM |
| SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| TERMINAL LENGTH | 2.250 INCHES NOMINAL |
| TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
| CASE MATERIAL | METAL |
| CASE INSULATION MATERIAL | PLASTIC |
| CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
| DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 19.0000 |
| DC LEAKAGE AT REFERENCE TEMP | 2.000 MICROAMPERES |
| ELECTRICAL POLARIZATION | POLARIZED |
| RELIABILITY INDICATOR | ESTABLISHED |
| RELIABILITY FAILURE RATE LEVEL IN PERCENT | 1.0000 |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| TEST DATA DOCUMENT | 81349-MIL-C-39006 TO 9 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |