NSN 5910-01-049-1741
Part Details | MICA DIELECTRIC FIXED CAPACITOR
5910-01-049-1741 A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.
Alternate Parts: CER3A2574SP9, CER3A2574SP-9, 138C674H09, 7245441, 724544-1, MP2BN104K, 5910-01-049-1741, 01-049-1741, 5910010491741, 010491741
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | OCT 13, 1977 | 01-049-1741 | 00005 ( CAPACITOR, FIXED, MICA DIELECTRIC ) |
REFERENCE DRAWINGS & PICTURES
W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE
NO COMMON OR GROUNDED ELECTRODE(S)
Cross Reference | NSN 5910-01-049-1741
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| CER3A2574SP-9 | 23280 | CUSTOM ELECTRONICS, INC. |
| 138C674H09 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NORTHROP GRUMMAN SYSTEMS |
| 724544-1 | 05869 | RAYTHEON COMPANYDBA RAYTHEON |
| MP2BN104K | 13058 | SORA POWER INC. |
Technical Data | NSN 5910-01-049-1741
| Characteristic | Specifications |
|---|---|
| CAPACITANCE VALUE PER SECTION | 100000.000 PICOFARADS SINGLE SECTION |
| TOLERANCE RANGE PER SECTION | -10.00 TO +10.00 PERCENT SINGLE SECTION |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 5000.0 DC SINGLE SECTION |
| TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS | -20.0 TO +50.0 SINGLE SECTION |
| NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
| BODY STYLE | W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE |
| BODY LENGTH | 5.000 INCHES NOMINAL |
| BODY WIDTH | 1.250 INCHES NOMINAL |
| BODY HEIGHT | 3.000 INCHES NOMINAL |
| SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| TERMINAL TYPE AND QUANTITY | 2 SOLDER STUD |
| TERMINAL LENGTH | 0.281 INCHES NOMINAL |
| CASE MATERIAL | GLASS |
| INSULATION RESISTANCE AT REFERENCE TEMP | 20000.0 MEGOHMS |
| DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.5000 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |