NSN 5910-01-061-9696
Part Details | CERAMIC DIELECTRIC FIXED CAPACITOR
5910-01-061-9696 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.
Alternate Parts: 5800583454003201, 5800583-454003-201, 332000X5F182K, 332-000X5F182K, 332000X5F182K, 332-000X5F182K, 5910-01-061-9696, 01-061-9696, 5910010619696, 010619696
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUL 07, 1978 | 01-061-9696 | 00007 ( CAPACITOR, FIXED, CERAMIC DIELECTRIC ) |
REFERENCE DRAWINGS & PICTURES
W/O MTG FACILITIES, RADIAL TERMINALS
NO COMMON OR GROUNDED ELECTRODE(S)
Cross Reference | NSN 5910-01-061-9696
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 5800583-454003-201 | C0426 | HENSOLDT SENSORS GMBH |
| 332-000X5F182K | 51406 | MURATA ERIE NORTH AMERICA INCHEADQUARTERS AND GEORGIA OPNS |
| 332-000X5F182K | 18796 | MURATA ERIE NORTH AMERICA INCSTATE COLLEGE OPNS |
Technical Data | NSN 5910-01-061-9696
| Characteristic | Specifications |
|---|---|
| CAPACITANCE VALUE PER SECTION | 1800.000 PICOFARADS SINGLE SECTION |
| TOLERANCE RANGE PER SECTION | -10.00 TO +10.00 PERCENT SINGLE SECTION |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 1000.0 DC SINGLE SECTION |
| VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE | BCNM7.5 TO +7.5 WITHOUT VOLTAGE APPLIED |
| NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| BODY STYLE | W/O MTG FACILITIES, RADIAL TERMINALS |
| BODY DIAMETER | 0.240 INCHES MAXIMUM |
| BODY LENGTH | 0.710 INCHES MAXIMUM |
| SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.375 INCHES NOMINAL |
| CASE MATERIAL | PLASTIC |
| INSULATION RESISTANCE AT REFERENCE TEMP | 50000.0 MEGOHMS |
| DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 2.0000 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |