NSN 5910-01-064-4080

Part Details | ELECTROLYTIC FIXED CAPACITOR

5910-01-064-4080 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Alternate Parts: 86F934H1, 3186GH503U050BH, 3186GH503U050AHA2, 539741903, 539-7419-03, 01802346, 0180-2346, 01802346, 0180-2346, CGS503U050X5L3PH, 36D4512DQB, 36D4512-DQB, 5910-01-064-4080, 01-064-4080, 5910010644080, 010644080

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59AUG 24, 197801-064-408000008 ( CAPACITOR, FIXED, ELECTROLYTIC )
REFERENCE DRAWINGS & PICTURES

W/O MTG FACILITIES, TERMINAL(S) ON ONE END

NO COMMON OR GROUNDED ELECTRODE(S)

Cross Reference | NSN 5910-01-064-4080
Part Number Cage Code Manufacturer
86F934H156699BC COMPONENTS
3186GH503U050BH56699BC COMPONENTS
3186GH503U050AHA256699BC COMPONENTS
539-7419-0300853CORNELL-DUBILIER MARKETING, INC.
0180-234628480HEWLETT-PACKARD COMPANYDBA HP
0180-23461LQK8KEYSIGHT TECHNOLOGIES, INC.
CGS503U050X5L3PH90201MALLORY SONALERT PRODUCTS INC.
36D4512-DQB56289SPRAGUE ELECTRIC COWORLD HQS
Technical Data | NSN 5910-01-064-4080
Characteristic Specifications
CAPACITANCE VALUE PER SECTION50000.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION-10.00 TO +75.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION50.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-20.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE W/O MTG FACILITIES, TERMINAL(S) ON ONE END
BODY DIAMETER3.031 INCHES NOMINAL
BODY LENGTH5.687 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY2 THREADED HOLE
TERMINAL DIAMETER0.190 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER1.250 INCHES NOMINAL
CASE MATERIAL METAL
CASE INSULATION MATERIAL PLASTIC
CAPACITIVE ELECTRODE MATERIAL ALUMINUM
EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS0.024
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR NOT ESTABLISHED
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS4.0