NSN 5910-01-088-3875

Part Details | MICA DIELECTRIC FIXED CAPACITOR

5910-01-088-3875 A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Alternate Parts: CMC334342, CMC-334-342, CEM3A123SP, SMA698364, SM-A-698364, 5910-01-088-3875, 01-088-3875, 5910010883875, 010883875

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 12, 198001-088-387500005 ( CAPACITOR, FIXED, MICA DIELECTRIC )
REFERENCE DRAWINGS & PICTURES

W/MTG TABS/FLANGES TERMINALS ON OPPOSITE SURFACES

NO COMMON OR GROUNDED ELECTRODE(S)

Cross Reference | NSN 5910-01-088-3875
Part Number Cage Code Manufacturer
CMC-334-34223280CUSTOM ELECTRONICS, INC.
CEM3A123SP23280CUSTOM ELECTRONICS, INC.
SM-A-69836480063US ARMY COMMUNICATIONS &ELECTRONICS MATERIEL READINESS
Technical Data | NSN 5910-01-088-3875
Characteristic Specifications
CAPACITANCE VALUE PER SECTION0.100 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION-10.00 TO +10.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION2000.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE W/MTG TABS/FLANGES TERMINALS ON OPPOSITE SURFACES
BODY LENGTH2.380 INCHES NOMINAL
BODY WIDTH1.450 INCHES MAXIMUM
BODY HEIGHT0.600 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG
TERMINAL LENGTH0.250 INCHES MAXIMUM
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED MOUNTING HOLES
UNTHREADED MOUNTING HOLE DIAMETER0.125 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.938 INCHES NOMINAL
INSULATION RESISTANCE AT REFERENCE TEMP300.0 MEGOHMS
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.500