Part Details | ELECTROLYTIC FIXED CAPACITOR

5910-01-100-4018 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Alternate Parts: 610746, 610746, T362C226M025AS, 5910-01-100-4018, 01-100-4018, 5910011004018, 011004018

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59SEP 06, 198001-100-401800008 ( CAPACITOR, FIXED, ELECTROLYTIC )
REFERENCE DRAWINGS & PICTURES

W/O MTG FACILITIES, TERMINAL(S) ON ONE END

NO COMMON OR GROUNDED ELECTRODE(S)

Cross Reference | NSN 5910-01-100-4018
Part Number Cage Code Manufacturer
61074625965AMETEK PROGRAMMABLE POWER, INC.DBA AMETEK PROGRAMMABLE POWER
61074616067CALIFORNIA INSTRUMENTS CORP
T362C226M025AS05397UNION CARBIDE CORP MATERIALS SYSTEMSDIV
Technical Data | NSN 5910-01-100-4018
Characteristic Specifications
CAPACITANCE VALUE PER SECTION22.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION-20.00 TO +20.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION25.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE W/O MTG FACILITIES, TERMINAL(S) ON ONE END
BODY DIAMETER0.350 INCHES MAXIMUM
BODY LENGTH0.650 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL LENGTH1.000 INCHES NOMINAL
TERMINAL DIAMETER0.025 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER0.250 INCHES NOMINAL
CASE MATERIAL PLASTIC
CAPACITIVE ELECTRODE MATERIAL TANTALUM
DC LEAKAGE AT REFERENCE TEMP10.000 MICROAMPERES
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR NOT ESTABLISHED