NSN 5910-01-119-1433
Part Details | PAPER-PLASTIC DIELECTRIC METALLIZED FIXED CAPACITOR
5910-01-119-1433 A capacitor whose capacitance value cannot be adjusted or varied having paper, plastic, or any combination of paper and plastic as the dielectric material with a metallic film deposited thereon. It may be a single unit or consist of two or more units which cannot be separated.
Alternate Parts: 3110496, 31-10496, 3110496, 31-10496, MR10665, MR106-6-5, 31105E5, 31-105E5, 5910-01-119-1433, 01-119-1433, 5910011191433, 011191433
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | SEP 19, 1981 | 01-119-1433 | 31959 ( CAPACITOR, FIXED, METALLIZED, PAPER-PLASTIC DIELECTRIC ) |
REFERENCE DRAWINGS & PICTURES
W/O MTG FACILITIES, AXIAL TERMINALS
NO COMMON OR GROUNDED ELECTRODE(S)
Cross Reference | NSN 5910-01-119-1433
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 31-10496 | 77820 | AMPHENOL CORPORATIONDBA AMPHENOL AEROSPACE OPERATIONS |
| 31-10496 | 02660 | AMPHENOL CORPSPECTRA-STRIP/ITD |
| MR106-6-5 | 04099 | CAPCO, LLC |
| 31-105E5 | 09134 | TEX-CAP INC |
Technical Data | NSN 5910-01-119-1433
| Characteristic | Specifications |
|---|---|
| CAPACITANCE VALUE PER SECTION | 1.000 MICROFARADS SINGLE SECTION |
| TOLERANCE RANGE PER SECTION | -5.00 TO +5.00 PERCENT SINGLE SECTION |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 600.0 DC SINGLE SECTION |
| NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALS |
| BODY DIAMETER | 0.775 INCHES NOMINAL |
| BODY LENGTH | 1.250 INCHES NOMINAL |
| SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| TERMINAL LENGTH | 1.625 INCHES MINIMUM |
| TERMINAL DIAMETER | 0.040 INCHES NOMINAL |
| CASE MATERIAL | PLASTIC |
| INSULATION RESISTANCE AT REFERENCE TEMP | 60000.0 MEGOHMS |
| DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 1.0000 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TERMINAL SURFACE TREATMENT | SOLDER |