NSN 5910-01-125-4350

Part Details | MICA DIELECTRIC FIXED CAPACITOR

5910-01-125-4350 A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Alternate Parts: 9123837001, 912-3837-001, 5910-01-125-4350, 01-125-4350, 5910011254350, 011254350

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 27, 198201-125-435000005 ( CAPACITOR, FIXED, MICA DIELECTRIC )
REFERENCE DRAWINGS & PICTURES

W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE

NO COMMON OR GROUNDED ELECTRODE(S)

Cross Reference | NSN 5910-01-125-4350
Part Number Cage Code Manufacturer
912-3837-00113499ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS
Technical Data | NSN 5910-01-125-4350
Characteristic Specifications
CAPACITANCE VALUE PER SECTION10.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION-0.50 TO +0.50 PICOFARADS SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION500.0 DC SINGLE SECTION
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS-200.0 TO +200.0 SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY LENGTH0.360 INCHES MAXIMUM
BODY WIDTH0.330 INCHES MAXIMUM
BODY HEIGHT0.190 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL LENGTH1.000 INCHES MINIMUM
TERMINAL DIAMETER0.016 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.150 INCHES NOMINAL
CASE MATERIAL PLASTIC
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
RELIABILITY INDICATOR NOT ESTABLISHED