NSN 5910-01-195-7249

Part Details | PAPER-PLASTIC DIELECTRIC METALLIZED FIXED CAPACITOR

5910-01-195-7249 A capacitor whose capacitance value cannot be adjusted or varied having paper, plastic, or any combination of paper and plastic as the dielectric material with a metallic film deposited thereon. It may be a single unit or consist of two or more units which cannot be separated.

Alternate Parts: 650C1A104K, DA2A104K, DA2A104K, 5910-01-195-7249, 01-195-7249, 5910011957249, 011957249

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59DEC 01, 198401-195-724931959 ( CAPACITOR, FIXED, METALLIZED, PAPER-PLASTIC DIELECTRIC )
REFERENCE DRAWINGS & PICTURES

W/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES

NO COMMON OR GROUNDED ELECTRODE(S)

Cross Reference | NSN 5910-01-195-7249
Part Number Cage Code Manufacturer
650C1A104K14752ELECTROCUBE, INC.DBA SOUTHERN ELECTRONICS
DA2A104K27556IMB ELECTRONIC PRODUCTS INC
DA2A104K15454RTIE HOLDINGS LLC
Technical Data | NSN 5910-01-195-7249
Characteristic Specifications
CAPACITANCE VALUE PER SECTION0.100 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION-10.00 TO +10.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION50.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE W/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES
BODY LENGTH0.530 INCHES NOMINAL
BODY WIDTH0.120 INCHES NOMINAL
BODY HEIGHT0.230 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL LENGTH1.500 INCHES MINIMUM
TERMINAL DIAMETER0.020 INCHES NOMINAL
CASE MATERIAL PLASTIC
INSULATION RESISTANCE AT REFERENCE TEMP25000.0 MEGOHM-MICROFARADS
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.5000
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL SURFACE TREATMENT SOLDER
END ITEM IDENTIFICATION1680-01-123-7659 APU CONTROL UNIT