NSN 5910-01-208-6473

Part Details | MICA DIELECTRIC FIXED CAPACITOR

5910-01-208-6473 A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Alternate Parts: 1601809, 160-1809, MD20312J1, MD20312J-1, MD20312J, 11436863, 5910-01-208-6473, 01-208-6473, 5910012086473, 012086473

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59MAY 17, 198501-208-647300005 ( CAPACITOR, FIXED, MICA DIELECTRIC )
REFERENCE DRAWINGS & PICTURES

W/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES

NO COMMON OR GROUNDED ELECTRODE(S)

Cross Reference | NSN 5910-01-208-6473
Part Number Cage Code Manufacturer
160-180913619EMS DEVELOPMENT CORPORATION
MD20312J-113058SORA POWER INC.
MD20312J13058SORA POWER INC.
1143686318876U S ARMY AVIATION AND MISSILECOMMAND
Technical Data | NSN 5910-01-208-6473
Characteristic Specifications
CAPACITANCE VALUE PER SECTION20000.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION-10.00 TO +10.00 PICOFARADS SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION2000.0 DC SINGLE SECTION
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS-0.0 TO +70.0 SINGLE SECTION
NONDERATED OPERATING TEMP-65.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE W/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES
BODY LENGTH1.438 INCHES NOMINAL
BODY WIDTH0.344 INCHES NOMINAL
BODY HEIGHT0.844 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL LENGTH2.000 INCHES MINIMUM
TERMINAL DIAMETER0.050 INCHES MAXIMUM
CASE MATERIAL PLASTIC
INSULATION RESISTANCE AT REFERENCE TEMP5000.0 MEGOHM-MICROFARADS
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.50000
RELIABILITY INDICATOR ESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT1.0000
TEST DATA DOCUMENT81349-MIL-C-39001 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TERMINAL SURFACE TREATMENT COPPER
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP25.0 MEGOHM-MICROFARADS