NSN 5910-01-214-6123

Part Details | ELECTROLYTIC FIXED CAPACITOR

5910-01-214-6123 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Alternate Parts: 634L50442, 634L504-42, LO3459, 5910-01-214-6123, 01-214-6123, 5910012146123, 012146123

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59AUG 14, 198501-214-612300008 ( CAPACITOR, FIXED, ELECTROLYTIC )
REFERENCE DRAWINGS & PICTURES

W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE

NO COMMON OR GROUNDED ELECTRODE(S)

Cross Reference | NSN 5910-01-214-6123
Part Number Cage Code Manufacturer
634L504-4224374BECHTEL TECHNICAL SERVICES INCMACHINERY APPARATUS OPN
LO345916236DLA LAND AND MARITIMEDBA ENGINEERING AND TECHNICAL
Technical Data | NSN 5910-01-214-6123
Characteristic Specifications
CAPACITANCE VALUE PER SECTION160.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION-15.00 TO +75.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION112.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE
BODY LENGTH1.275 INCHES NOMINAL
BODY WIDTH0.783 INCHES NOMINAL
BODY HEIGHT2.500 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG
TERMINAL LENGTH0.364 INCHES NOMINAL
CASE MATERIAL METAL
CAPACITIVE ELECTRODE MATERIAL TANTALUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT15.0000
DC LEAKAGE AT REFERENCE TEMP84.000 MICROAMPERES
ELECTRICAL POLARIZATION NONPOLARIZED
RELIABILITY INDICATOR NOT ESTABLISHED
FEATURES PROVIDED HERMETICALLY SEALED CASE
SPECIAL FEATURESITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO3459
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSREFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP
CRITICALITY CODE JUSTIFICATIONZZZY
TERMINAL SURFACE TREATMENT SOLDER
ANODE TYPE ETCHED FOIL
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS25.0
DC LEAKAGE AT MAXIMUM OPERATING TEMP670.0 MICROAMPERES