NSN 5910-01-291-4011
Part Details | ELECTROLYTIC FIXED CAPACITOR
5910-01-291-4011 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.
Alternate Parts: MILC5536504, MIL-C-55365/04, CWR06KA106KP, 5910-01-291-4011, 01-291-4011, 5910012914011, 012914011
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | DEC 28, 1988 | 01-291-4011 | 00008 ( CAPACITOR, FIXED, ELECTROLYTIC ) |
REFERENCE DRAWINGS & PICTURES
CHIP TYPE
ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
Cross Reference | NSN 5910-01-291-4011
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| MIL-C-55365/04 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| CWR06KA106KP | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5910-01-291-4011
| Characteristic | Specifications |
|---|---|
| CAPACITANCE VALUE PER SECTION | 10.000 MICROFARADS SINGLE SECTION |
| TOLERANCE RANGE PER SECTION | -10.00 TO +10.00 PERCENT SINGLE SECTION |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 25.0 DC SINGLE SECTION |
| NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
| BODY STYLE | CHIP TYPE |
| BODY LENGTH | 0.265 INCHES NOMINAL |
| BODY WIDTH | 0.110 INCHES NOMINAL |
| BODY HEIGHT | 0.110 INCHES NOMINAL |
| SCHEMATIC DIAGRAM DESIGNATOR | ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL |
| TERMINAL TYPE AND QUANTITY | 2 BONDING PAD |
| CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
| ELECTRICAL POLARIZATION | POLARIZED |
| RELIABILITY INDICATOR | ESTABLISHED |
| RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.100 |
| TEST DATA DOCUMENT | 81349-MIL-C-55365 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |