NSN 5910-01-433-2914

Part Details | CERAMIC DIELECTRIC FIXED CAPACITOR

5910-01-433-2914 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Alternate Parts: 87106433, 87106-433, 87106433, 87106-433, 87106433, 87106-433, 87106433, 87106-433, 87106433, 87106-433, 87106433, 87106-433, 87106433, 87106-433, 87106433, 87106-433, 5910-01-433-2914, 01-433-2914, 5910014332914, 014332914

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUN 26, 199601-433-291400007 ( CAPACITOR, FIXED, CERAMIC DIELECTRIC )
REFERENCE DRAWINGS & PICTURES

DUAL INLINE

NO COMMON OR GROUNDED ELECTRODE(S)

Cross Reference | NSN 5910-01-433-2914
Part Number Cage Code Manufacturer
87106-43304222AVX CORPORATIONDBA OLEAN ADVANCED PRODUCTS
87106-43367268DLA LAND AND MARITIMEDBA ENGINEERING AND TECHNICAL
87106-433037Z3DLA LAND AND MARITIMEDBA ENGINEERING AND TECHNICAL
87106-43358421GREATBATCH SIERRA INC
87106-43379474GREATBATCH SIERRA INCDBA USE CAGE CODE 58421 FOR
87106-43329454JOHANSON DIELECTRICS INC
87106-4330BMH6MICROSEMI CORP MICRO-CERAMXTECHNOLOGY DIV
87106-4330YBX7UNION TECHNOLOGY CORPORATIONDIV UNION TECHNOLOGY CORP.
Technical Data | NSN 5910-01-433-2914
Characteristic Specifications
CAPACITANCE VALUE PER SECTION470.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION-10.00 TO +10.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION500.0 DC SINGLE SECTION
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGEC45.0 TO +15.0 WITH RATED VOLTAGE APPLIED
NONDERATED OPERATING TEMP-55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE DUAL INLINE
BODY LENGTH0.224 INCHES MINIMUM AND 0.275 INCHES MAXIMUM
BODY WIDTH0.300 INCHES MAXIMUM
BODY HEIGHT0.360 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY6 UNINSULATED WIRE LEAD
TERMINAL LENGTH0.060 INCHES MINIMUM AND 0.080 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.100 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.250 INCHES NOMINAL
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT2.500
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL SURFACE TREATMENT SOLDER
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP10000.0 MEGOHMS