NSN 5910-01-467-8143
Part Details | CERAMIC DIELECTRIC FIXED CAPACITOR
5910-01-467-8143 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.
Alternate Parts: MILPRF2036, MIL-PRF-20/36, MILC2036, MIL-C-20/36, CCR06CG102FRV, 5910-01-467-8143, 01-467-8143, 5910014678143, 014678143
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | SEP 15, 1999 | 01-467-8143 | 00007 ( CAPACITOR, FIXED, CERAMIC DIELECTRIC ) |
REFERENCE DRAWINGS & PICTURES
W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
NO COMMON OR GROUNDED ELECTRODE(S)
Cross Reference | NSN 5910-01-467-8143
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| MIL-PRF-20/36 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-C-20/36 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| CCR06CG102FRV | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5910-01-467-8143
| Characteristic | Specifications |
|---|---|
| CAPACITANCE VALUE PER SECTION | 1000.000 PICOFARADS SINGLE SECTION |
| TOLERANCE RANGE PER SECTION | -1.00 TO +1.00 PERCENT SINGLE SECTION |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 200.0 DC SINGLE SECTION |
| TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | 0.0 SINGLE SECTION |
| TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS | -30.0 TO +30.0 SINGLE SECTION |
| NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
| BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
| BODY LENGTH | 7.1 MILLIMETERS MINIMUM AND 7.6 MILLIMETERS MAXIMUM |
| BODY WIDTH | 7.1 MILLIMETERS MINIMUM AND 7.6 MILLIMETERS MAXIMUM |
| BODY HEIGHT | 2.1 MILLIMETERS MINIMUM AND 2.5 MILLIMETERS MAXIMUM |
| SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| TERMINAL HEIGHT FROM BODY | 31.8 MILLIMETERS MINIMUM |
| TERMINAL DIAMETER | 0.6 MILLIMETERS MINIMUM AND 0.7 MILLIMETERS MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 4.4 MILLIMETERS MINIMUM AND 4.9 MILLIMETERS MAXIMUM |
| RELIABILITY INDICATOR | ESTABLISHED |
| RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
| SPECIFICATION/STANDARD DATA | 81349-MIL-C-20 TO 36 GOVERNMENT SPECIFICATION |