NSN 5915-00-110-0803
Part Details | BAND PASS FILTER
5915-00-110-0803 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).
Alternate Parts: 328037051, 32-803705-1, 328037051, 32-803705-1, P012A, CFA1210, 5915-00-110-0803, 00-110-0803, 5915001100803, 001100803
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | AUG 09, 1968 | 00-110-0803 | 00209 ( FILTER, BAND PASS ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
Cross Reference | NSN 5915-00-110-0803
Part Number | Cage Code | Manufacturer |
---|---|---|
32-803705-1 | 07397 | GENERAL DYNAMICS ADVANCEDINFORMATION SYSTEMS INC. |
32-803705-1 | 25120 | PIEZO TECHNOLOGY, INC.DBA MTRON PTI |
P012A | 11869 | ST OLEKTRON CORP |
CFA1210 | 11869 | ST OLEKTRON CORP |
Technical Data | NSN 5915-00-110-0803
Characteristic | Specifications |
---|---|
REFERENCE FREQUENCY PER FUNCTION | ZZ100.0 KILOHERTZ |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 BLANK |
FREQUENCY BAND WIDTH PER FUNCTION | ZZ99.90 KILOHERTZ AND ZZ100.10 KILOHERTZ |
SOURCE IMPEDANCE RATING PER FUNCTION | ZZ200.0 OHMS |
LOAD IMPEDANCE PER FUNCTION | ZZ200.0 OHMS |
INCLOSURE TYPE | ENCASED |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
OVERALL HEIGHT | 1.000 INCHES MAXIMUM |
OVERALL WIDTH | 1.250 INCHES MAXIMUM |
BODY LENGTH | 2.380 INCHES MAXIMUM |
BODY HEIGHT | 0.750 INCHES MAXIMUM |
BODY WIDTH | 1.250 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.875 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
NOMINAL THREAD SIZE | 0.112 INCHES |
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | ZZ99.40 KILOHERTZ AND ZZ99.90 KILOHERTZ AND ZZ100.10 KILOHERTZ AND ZZ100.60 KILOHERTZ |
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | ZZ30.0 MINIMUM AND ZZ3.0 MAXIMUM AND ZZ3.0 MAXIMUM AND ZZ30.0 MINIMUM |
OPERATING TEMP RANGE | +0.0 TO +50.0 DEG CELSIUS |