NSN 5915-00-910-7123
Part Details | BAND PASS FILTER
5915-00-910-7123 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).
Alternate Parts: 1620530, 162-0530, FL0109, 5269614010, 526-9614-010, 5915-00-910-7123, 00-910-7123, 5915009107123, 009107123
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1960 | 00-910-7123 | 00209 ( FILTER, BAND PASS ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
Cross Reference | NSN 5915-00-910-7123
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 162-0530 | 14304 | HARRIS CORPORATIONDBA HARRIS RF COMMUNICATION |
| FL0109 | 14304 | HARRIS CORPORATIONDBA HARRIS RF COMMUNICATION |
| 526-9614-010 | 95105 | ROCKWELL COLLINS, INC.DIV GOVERNMENT SYSTEMS - DALLAS |
Technical Data | NSN 5915-00-910-7123
| Characteristic | Specifications |
|---|---|
| REFERENCE FREQUENCY PER FUNCTION | K455.0 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | ZZ.5 |
| FREQUENCY BAND WIDTH PER FUNCTION | -454.55 AND -455.45 |
| SOURCE IMPEDANCE RATING PER FUNCTION | K50.0 |
| LOAD IMPEDANCE PER FUNCTION | Q500.0 |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
| OVERALL HEIGHT | 0.985 INCHES NOMINAL |
| BODY LENGTH | 2.734 INCHES MAXIMUM |
| BODY HEIGHT | 0.766 INCHES MAXIMUM |
| BODY WIDTH | 0.500 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | AET |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.492 INCHES MINIMUM AND 1.508 INCHES MAXIMUM |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.192 INCHES MINIMUM AND 0.208 INCHES MAXIMUM |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
| NOMINAL THREAD SIZE | 0.112 INCHES |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | -454.55 AND -454.73 AND -455.27 AND -455.45 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | A70.0 AND A3.5 AND A3.5 AND A70.0 |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | AB |
| OPERATING TEMP RANGE | -40.0 TO +75.0 DEG CELSIUS |
| BODY MATERIAL | METAL |