NSN 5915-00-914-5341
Part Details | BAND PASS FILTER
5915-00-914-5341 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).
Alternate Parts: 00102, 001-02, 0800334000, 08-00334-000, 5915-00-914-5341, 00-914-5341, 5915009145341, 009145341
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | FEB 14, 1966 | 00-914-5341 | 00209 ( FILTER, BAND PASS ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
Cross Reference | NSN 5915-00-914-5341
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 001-02 | 59492 | QUARTZTEK INC |
| 08-00334-000 | 00724 | RAYTHEON COMPANYDBA RAYTHEON |
Technical Data | NSN 5915-00-914-5341
| Characteristic | Specifications |
|---|---|
| REFERENCE FREQUENCY PER FUNCTION | -5.1250 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | ZZ0 |
| FREQUENCY BAND WIDTH PER FUNCTION | -5.083 AND -5.167 |
| INPUT IMPEDANCE PER FUNCTION W/LOAD | Q50.0 |
| OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | Q50.0 |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
| OVERALL HEIGHT | 1.118 INCHES MINIMUM AND 1.182 INCHES MAXIMUM |
| BODY LENGTH | 2.234 INCHES MINIMUM AND 2.266 INCHES MAXIMUM |
| BODY HEIGHT | 0.784 INCHES MINIMUM AND 0.816 INCHES MAXIMUM |
| BODY WIDTH | 0.980 INCHES MINIMUM AND 1.020 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | AET |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.585 INCHES MINIMUM AND 1.695 INCHES MAXIMUM |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.595 INCHES MINIMUM AND 0.605 INCHES MAXIMUM |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
| NOMINAL THREAD SIZE | 0.112 INCHES |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | -4.995 AND -5.083 AND -5.167 AND -5.255 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | B80.0 AND C6.0 AND C6.0 AND B80.0 |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | AD |
| AVERAGE LIFE RATING IN HOURS | 10000.0 |
| OPERATING TEMP RANGE | -55.0 TO +85.0 DEG CELSIUS |