NSN 5915-00-978-4205
Part Details | BAND PASS FILTER
5915-00-978-4205 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).
Alternate Parts: 268B, 293084400, 293-0844-00, 2930844000, 293-0844-000, 293084400, 293-0844-00, 293084400, 293-0844-00, 5915-00-978-4205, 00-978-4205, 5915009784205, 009784205
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | OCT 21, 1966 | 00-978-4205 | 00209 ( FILTER, BAND PASS ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
Cross Reference | NSN 5915-00-978-4205
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 268B | 28726 | BULOVA TECHNOLOGIES L.L.C.DBA ENVIRONMENTAL SYSTEMS & SVCS |
| 293-0844-00 | 22929 | DALE ELECTRONICS INCFREQUENCY CONTROL GROUP |
| 293-0844-000 | 13499 | ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS |
| 293-0844-00 | 13499 | ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS |
| 293-0844-00 | 00136 | VECTRON INTERNATIONAL, INC. |
Technical Data | NSN 5915-00-978-4205
| Characteristic | Specifications |
|---|---|
| REFERENCE FREQUENCY PER FUNCTION | K100.0 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | ZZ0 |
| FREQUENCY BAND WIDTH PER FUNCTION | K99.96 AND K100.04 |
| INPUT IMPEDANCE PER FUNCTION W/LOAD | Q5.0 |
| OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | Q10.0 |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
| BODY LENGTH | 2.172 INCHES MINIMUM AND 2.204 INCHES MAXIMUM |
| BODY HEIGHT | 2.484 INCHES MINIMUM AND 2.516 INCHES MAXIMUM |
| BODY WIDTH | 0.875 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | AET |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
| NOMINAL THREAD SIZE | 0.138 INCHES |
| TEST DATA DOCUMENT | 13499-293-0844-000 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | K99.60 AND K99.96 AND K100.04 AND K100.40 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | A40.00 AND A3.00 AND A3.00 AND A40.00 |
| OPERATING TEMP RANGE | -55.0 TO +75.0 DEG CELSIUS |