NSN 5920-00-084-3657
Part Details | CARTRIDGE FUSE
5920-00-084-3657 A fuse in which the element is inclosed in a cylindrical body. The element may be renewable. The terminals may be of varying types. It may contain a visual indication that the fusible element is severed, and may also provide an audible alarm through auxiliary circuitry. For noncylindrical items, see FUSE, INCLOSED LINK.
Alternate Parts: 272500, 00020308G, 2043076, 5L481100380, 5L4811-003-80, 5L.4811.003.80, 272500, 272-500, 43.10264, 43.0314, 43.00314, 19278.500K, 278.500K, 272500, 272-500, 00020308G, 241108601015, 110315763, 11031576-3, 19278.500K, 278.500K, 5920-00-084-3657, 00-084-3657, 5920000843657, 000843657
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 01, 1963 | 00-084-3657 | 00248 ( FUSE, CARTRIDGE ) |
REFERENCE DRAWINGS & PICTURES
PLUG-IN TYPE
Cross Reference | NSN 5920-00-084-3657
Part Number | Cage Code | Manufacturer |
---|---|---|
272500 | F2127 | A JAHNICHEN SA |
00020308G | F9073 | AIRBUS DS SAS |
2043076 | D1765 | HAGENUK MARINEKOMMUNIKATION GMBH |
5L4811-003-80 | D1901 | HENSOLDT SENSORS GMBHDIV SEPS |
5L.4811.003.80 | D1901 | HENSOLDT SENSORS GMBHDIV SEPS |
272-500 | 0EFK4 | INTERNATIONAL TELEVISION CORPDBA I T C ELECTRONICS |
43.10264 | C0220 | KLUXEN, WALTER GMBH |
43.0314 | C0220 | KLUXEN, WALTER GMBH |
43.00314 | C0220 | KLUXEN, WALTER GMBH |
19278.500K | DN837 | LITTELFUSE GMBH |
278.500K | DN837 | LITTELFUSE GMBH |
272-500 | 75915 | LITTELFUSE, INC. |
00020308G | F0220 | PAULSTRA SNC |
241108601015 | D9645 | THALES ELECTRONIC SYSTEMS GMBHDIV NAVAL |
11031576-3 | 18876 | U S ARMY AVIATION AND MISSILECOMMAND |
19278.500K | D3841 | WICKMANN WERKE GMBH |
278.500K | D3841 | WICKMANN WERKE GMBH |
Technical Data | NSN 5920-00-084-3657
Characteristic | Specifications |
---|---|
BODY STYLE | PLUG-IN TYPE |
OVERALL LENGTH | 0.460 INCHES NOMINAL |
TERMINAL LENGTH | 0.170 INCHES NOMINAL |
BODY LENGTH | 0.290 INCHES NOMINAL |
OVERALL DIAMETER | 0.230 INCHES MINIMUM AND 0.240 INCHES MAXIMUM |
TERMINAL DIAMETER | 0.094 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO DIAMETER | 0.100 INCHES NOMINAL |
CONTINUOUS CURRENT RATING IN AMPS | 0.500 |
MAXIMUM VOLTAGE RATING IN VOLTS | 125.0 AC AND 125.0 DC |
CIRCUIT OVER-CURRENT INTERRUPTION TYPE | NORMAL INSTANTANEOUS |
SHORT-CIRCUIT/INTERRUPT CURRENT RATING IN AMPS | 10000.0 |
INTERRUPTION INDICATOR METHOD | VISIBLE ELEMENT |
TERMINAL SURFACE TREATMENT | SOLDER DIP |
FEATURES PROVIDED | NONRENEWABLE FUSIBLE ELEMENT |