NSN 5925-01-469-3103
Part Details | CIRCUIT BREAKER
5925-01-469-3103 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
Alternate Parts: AF1BO34610IF, AF1-BO-34-610-IF, 5925-01-469-3103, 01-469-3103, 5925014693103, 014693103
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | NOV 10, 1999 | 01-469-3103 | 00136 ( CIRCUIT BREAKER ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5925-01-469-3103
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| AF1-BO-34-610-IF | 73559 | CARLING TECHNOLOGIES, INCDBA CARLINGSWITCH |
Technical Data | NSN 5925-01-469-3103
| Characteristic | Specifications |
|---|---|
| RESET METHOD | MANUAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | NONTRIP FREE |
| BODY LENGTH | 57.0 MILLIMETERS MINIMUM AND 59.0 MILLIMETERS MAXIMUM |
| BODY WIDTH | 18.0 MILLIMETERS MINIMUM AND 19.0 MILLIMETERS MAXIMUM |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | 59.0 MILLIMETERS MINIMUM AND 61.0 MILLIMETERS MAXIMUM |
| MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC AND 65.0 DC |
| SPECIAL FEATURES | 50/60 HZ AC |