NSN 5925-01-515-5785

Part Details | CIRCUIT BREAKER

5925-01-515-5785 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: 168003710050, 1680-037-100-50, 5925-01-515-5785, 01-515-5785, 5925015155785, 015155785

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59DEC 01, 200301-515-578500136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

SINGLE POLE TYPE

Cross Reference | NSN 5925-01-515-5785
Part Number Cage Code Manufacturer
1680-037-100-5081640SAFRAN ELECTRICAL & POWER USA, LLCDBA LABINAL POWER SYSYEMS
Technical Data | NSN 5925-01-515-5785
Characteristic Specifications
RESET METHOD MANUAL
BODY STYLE SINGLE POLE TYPE
OVERALL LENGTH1.380 INCHES NOMINAL
BODY WIDTH0.560 INCHES NOMINAL
SPECIAL FEATURES5.0 TO 35. AMPS;SNAP ACTING BIMETALLIC THERMAL SENSING ELEMENT SYSTEM
END ITEM IDENTIFICATIONBENFORD TV 1200
PART NAME ASSIGNED BY CONTROLLING AGENCYPUSH TO RESET CIRCUIT BREAKER