NSN 5925-01-610-5718

Part Details | CIRCUIT BREAKER

5925-01-610-5718 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: PR11015.0AXXV, PR11-0-15.0A-XX-V, 5925-01-610-5718, 01-610-5718, 5925016105718, 016105718

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59AUG 22, 201201-610-571800136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

SINGLE POLE TYPE

Cross Reference | NSN 5925-01-610-5718
Part Number Cage Code Manufacturer
PR11-0-15.0A-XX-V51913WALKER POWER SYSTEMS, INC.DBA TIERNAY TURBINES
Technical Data | NSN 5925-01-610-5718
Characteristic Specifications
POLE QUANTITY1
TERMINAL TYPE AND QUANTITY2 SCREW BASE
BODY STYLE SINGLE POLE TYPE
ACTUATOR POSITION DESIGNATION AT POLE FOUR
AUXILIARY SWITCH FUNCTION AND QUANTITY1 CONTROL
SWITCH LOCATION AND POSITION DESIGNATION EXTERNAL AT POLE ONE
SPECIAL FEATURESMP BUTTON MARKINGS DESIRED; VDE, TUV AND CCC APPROVED
END ITEM IDENTIFICATION2350-01-087-1095
PART NAME ASSIGNED BY CONTROLLING AGENCYTOGGLE ACTUATOR