NSN 5925-01-617-4501
Part Details | CIRCUIT BREAKER
5925-01-617-4501 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
Alternate Parts: A1103422 ITEM 0020, A1-103422 ITEM 0020, AM3RA8LC15KAB76, AM3R-A8-LC-15-K-AB-7-6, AM3RA8LC15KAB76, AM3R-A8-LC-15-K-AB-7-6, 5925-01-617-4501, 01-617-4501, 5925016174501, 016174501
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | MAR 22, 2013 | 01-617-4501 | 00136 ( CIRCUIT BREAKER ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5925-01-617-4501
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| A1-103422 ITEM 0020 | K0735 | AISH TECHNOLOGIES LTD |
| AM3R-A8-LC-15-K-AB-7-6 | 81118 | EATON CORPORATIONDBA FLUID POWER PLANT |
| AM3R-A8-LC-15-K-AB-7-6 | L3330 | HEINEMANN ELECTRIC CANADA INCDIVISION OF EATON CORP |
Technical Data | NSN 5925-01-617-4501
| Characteristic | Specifications |
|---|---|
| POLE QUANTITY | 3 |
| OVERALL LENGTH | 2.860 INCHES NOMINAL |
| OVERALL HEIGHT | 2.740 INCHES NOMINAL |
| OVERALL WIDTH | 0.750 INCHES NOMINAL |
| SPECIAL FEATURES | 8 INTERNAL CIRCUITS; SERIES TRIP; INRUSH 18X; BLACK HANDLE; M3-0.5 MOUNT; M5 THREADS 70A; |
| END ITEM IDENTIFICATION | FORWARD MBT CIRCUIT |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | HEINEMANN AM/R SERIES CIRCUIT BREAKER |