NSN 5925-01-651-1776

Part Details | CIRCUIT BREAKER

5925-01-651-1776 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: 7182, 5925-01-651-1776, 01-651-1776, 5925016511776, 016511776

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 07, 201601-651-177600136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5925-01-651-1776
Part Number Cage Code Manufacturer
718209KQ8BLUE SEAS SCUBA CENTER
Technical Data | NSN 5925-01-651-1776
Characteristic Specifications
POLE QUANTITY2
SPECIAL FEATURESINTERRUPTING CAPACITY 3,000 A @ 48V DC; TEMPERATURE MINIMUM OPERATING: MINUS 40 DEGREES; MAXIMUM OPERATING TEMPERATURE 85 DEGREES; TYPE: THERMALLY RESPONSIVE BI-METAL DISC; CLASS: TYPE III, SWITCHABLE MANUAL RESET - TRIP FREE; TERMINAL STUD M6 (ACCEPT 1/4" RING TERMINAL); MOUNTING HOLE: ACCEPT 1/4" SCREW; DROP IN REPLACEMENT FOR THE 185-SERIES PANEL AND SURFACE MOUNT THERMAL CIRCUIT BREAKER
PART NAME ASSIGNED BY CONTROLLING AGENCY285 SERIES THERMAL CIRCUIT BREAKERS