NSN 5930-00-081-3126
Part Details | PRESSURE SWITCH
5930-00-081-3126 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 75180991127, 7545304, 754530401, 7545304-01, 8267, 1193P13, 5930-00-081-3126, 00-081-3126, 5930000813126, 000813126
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 01, 1963 | 00-081-3126 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-081-3126
Part Number | Cage Code | Manufacturer |
---|---|---|
75180991127 | 58918 | AEROSPACE CONTROL PRODUCTS, INC. |
7545304 | 97151 | AIR FORCE LIFECYCLE MANAGEMENTCENTER ELECTRONIC COMPONENTS |
7545304-01 | 09049 | CUSTOM CONTROL SENSORS, LLCDBA CUSTOM AVIATION SUPPLY |
8267 | 98505 | HYDRA-ELECTRIC COMPANY |
1193P13 | 98087 | ITT AEROSPACE CONTROLS LLCDBA ITT AEROSPACE CONTROLS UNIT S |
Technical Data | NSN 5930-00-081-3126
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 8 CYLINDRICAL W/FLANGE |
OVERALL LENGTH | 3.100 INCHES NOMINAL |
BODY LENGTH | 1.900 INCHES MAXIMUM |
OVERALL DIAMETER | 0.870 INCHES MAXIMUM |
PRESSURE SWITCH TYPE | ABSOLUTE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | DECREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | BC14.25 ACTUATION POINT NOMINAL AND BC15.75 DEACTUATION POINT NOMINAL AND BC1.50 DIFFERENTIAL POINT NOMINAL |
OPERATING TEMP RATING | -65.0 DEG CELSIUS MINIMUM AND 93.0 DEG CELSIUS MAXIMUM |
MEDIA FOR WHICH DESIGNED | GAS |
PROOF PRESSURE | 50.00 POUNDS PER SQUARE INCH ABSOLUTE |
TERMINAL TYPE | TAB, SOLDER LUG |
MOUNTING METHOD | INLET CONNECTION |