NSN 5930-00-081-4814
Part Details | THERMOSTATIC SWITCH
5930-00-081-4814 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 0101419, 010-1419, 0101419, 010-1419, 5930-00-081-4814, 00-081-4814, 5930000814814, 000814814
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | DEC 08, 1967 | 00-081-4814 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR

Cross Reference | NSN 5930-00-081-4814
Part Number | Cage Code | Manufacturer |
---|---|---|
010-1419 | 50992 | RANCO INCRANCO CONTROLS DIV |
010-1419 | 49742 | RANCO MANAGEMENT CORP |
Technical Data | NSN 5930-00-081-4814
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 2 RECTANGULAR |
OVERALL LENGTH | 3.469 INCHES MAXIMUM |
OVERALL HEIGHT | 4.813 INCHES MAXIMUM |
OVERALL WIDTH | 2.000 INCHES MAXIMUM |
BODY LENGTH | 3.469 INCHES MAXIMUM |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET AND DEACTUATION POINT ADJUSTABLE, PRESET |
CONTACT ADJUSTMENT RANGE | -35.00 TO +0.00 ACTUATION POINT DEGREES FAHRENHEIT AND -35.00 TO +0.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB AND EXTERNAL DEACTUATION POINT KNOB |
CONTACT STIMULUS RATING | AF0.00 ACTUATION POINT NOMINAL AND AFM4.00 DEACTUATION POINT NOMINAL |
MEDIA FOR WHICH DESIGNED | Q$DADF |
TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE |
CAPILLARY TUBE LENGTH | 76.0 INCHES NOMINAL |
TERMINAL TYPE | SCREW |
MOUNTING METHOD | THREADED HOLE |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.000 INCHES NOMINAL |
FEATURES PROVIDED | ELECTRICAL ACCESS PORT AND AUTOMATIC RESET |