NSN 5930-00-134-0379
Part Details | PRESSURE SWITCH
5930-00-134-0379 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 150151, 15015-1, M9395101, M9395/1-01, MILDTL93951, MIL-DTL-9395/1, 5930-00-134-0379, 00-134-0379, 5930001340379, 001340379
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | NOV 15, 1968 | 00-134-0379 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-134-0379
Part Number | Cage Code | Manufacturer |
---|---|---|
15015-1 | 98505 | HYDRA-ELECTRIC COMPANY |
M9395/1-01 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-DTL-9395/1 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5930-00-134-0379
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 5.090 INCHES NOMINAL |
OVERALL HEIGHT | 2.030 INCHES MAXIMUM |
OVERALL WIDTH | 3.590 INCHES MAXIMUM |
PRESSURE SWITCH TYPE | GAGE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | BD1500.00 ACTUATION POINT NOMINAL AND BD1300.00 DEACTUATION POINT NOMINAL AND BD200.00 DIFFERENTIAL POINT NOMINAL |
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM |
PROOF PRESSURE | 4500.00 POUNDS PER SQUARE INCH |
TERMINAL TYPE | CONNECTOR, RECEPTACLE |
MOUNTING METHOD | BRACKET |
SPECIAL FEATURES | THREE MTG HOLES 0.203 IN. DIA IN. LINE SPACED 1/310 IN. C TO C |
TEST DATA DOCUMENT | 81349-MIL-S-9395 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SENSING ELEMENT BURST PRESSURE | 7500.00 POUNDS PER SQUARE INCH |