NSN 5930-00-147-7632

Part Details | ROTARY SWITCH

5930-00-147-7632 A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).

Alternate Parts: 5930001477632, 44S300326N, 44S30-03-2-6N, 44MS300326N, 44MS30-03-2-6N, 44HS300326N, 44HS30-03-2-6N, 4M30F23N6, 4M30F2-3N6, M3786145060, M378614-5060, M378645060, M3786/4-5060, MILS37864, MIL-S-3786/4, MILDTL37864, MIL-DTL-3786/4, 5930-00-147-7632, 00-147-7632, 5930001477632, 001477632

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59OCT 01, 197100-147-763202134 ( SWITCH, ROTARY )
REFERENCE DRAWINGS & PICTURES

TAP, CIRCULAR, BUSHING MOUNT

Cross Reference | NSN 5930-00-147-7632
Part Number Cage Code Manufacturer
5930001477632SCY13E.C.A ETABLISSEMENTCENTRALD'APPROVISIONNEMENT DES
44S30-03-2-6N81073GRAYHILL, INC
44MS30-03-2-6N81073GRAYHILL, INC
44HS30-03-2-6N81073GRAYHILL, INC
4M30F2-3N691812JANCO CORPORATIONDBA ESTERLINE MASON
M378614-506081349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
M3786/4-506081349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-S-3786/481349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-DTL-3786/481349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
Technical Data | NSN 5930-00-147-7632
Characteristic Specifications
STYLE DESIGNATOR TAP, CIRCULAR, BUSHING MOUNT
OVERALL LENGTH2.427 INCHES MINIMUM AND 2.755 INCHES MAXIMUM
OVERALL DIAMETER1.100 INCHES MINIMUM AND 1.306 INCHES MAXIMUM
INDIVIDUAL SECTION QUANTITY3
SWITCH CONTACT BASIC DESIGN NONPILE-UP SYMMETRICAL
TERMINAL TYPE TAB, SOLDER LUG
SPECIAL FEATURESFEATGNONE
TEST DATA DOCUMENT81349-MIL-S-3786 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION EXPLOSION PROOF
OPERATING TEMP RANGE-65.0 TO +125.0 DEG CELSIUS