NSN 5930-00-189-4097
Part Details | PRESSURE SWITCH
5930-00-189-4097 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 675GHM323S, 75102, SMA570847, SM-A-570847, 5930-00-189-4097, 00-189-4097, 5930001894097, 001894097
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | MAR 03, 1971 | 00-189-4097 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR

Cross Reference | NSN 5930-00-189-4097
Part Number | Cage Code | Manufacturer |
---|---|---|
675GHM323S | 09049 | CUSTOM CONTROL SENSORS, LLCDBA CUSTOM AVIATION SUPPLY |
75102 | 98505 | HYDRA-ELECTRIC COMPANY |
SM-A-570847 | 80063 | US ARMY COMMUNICATIONS &ELECTRONICS MATERIEL READINESS |
Technical Data | NSN 5930-00-189-4097
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 7 RECTANGULAR |
OVERALL LENGTH | 4.400 INCHES MAXIMUM |
BODY LENGTH | 3.550 INCHES NOMINAL |
OVERALL DIAMETER | 5.000 INCHES NOMINAL |
PRESSURE SWITCH TYPE | ABSOLUTE |
NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | BC16.00 ACTUATION POINT NOMINAL |
MEDIA FOR WHICH DESIGNED | GAS |
PROOF PRESSURE | 15.00 POUNDS PER SQUARE INCH GAGE |
TERMINAL TYPE | CONNECTOR, RECEPTACLE |
MOUNTING METHOD | INLET CONNECTION |