NSN 5930-00-260-5059

Part Details | THERMOSTATIC SWITCH

5930-00-260-5059 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: B458822REV1PT1, M7406282PT4, M-7406282PT4, C8151818, C8151-818, C8151858, C8151-858, 5930-00-260-5059, 00-260-5059, 5930002605059, 002605059

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-260-505900451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-260-5059
Part Number Cage Code Manufacturer
B458822REV1PT149671LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
M-7406282PT497942NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NORTHROP GRUMMAN SYSTEMS
C8151-81882647SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO
C8151-85882641SHATTUCK FRANK G CO
Technical Data | NSN 5930-00-260-5059
Characteristic Specifications
STYLE DESIGNATOR5 CYLINDRICAL W/FLANGE
OVERALL HEIGHT0.781 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATINGAE53.00 ACTUATION POINT MINIMUM AND AE57.00 ACTUATION POINT MAXIMUM AND AE40.00 DEACTUATION POINT MINIMUM AND AE45.00 DEACTUATION POINT MAXIMUM AND AE13.00 DIFFERENTIAL POINT NOMINAL
OPERATING TEMP RATING530.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNEDQ$DADF
TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
TERMINAL TYPE TAB W/SCREW
MOUNTING METHOD FLANGE AND UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.154 INCHES NOMINAL
MOUNTING FACILITY PATTERN FOUR POSITION CIRCULAR
MOUNTING FACILITY CIRCLE RADIUS1.064 INCHES NOMINAL
FEATURES PROVIDED TAMPER PROOF CAP
SPECIAL FEATURESONE 0.5 UF CAPACITOR IN SERIES W/ONE 1 OHM RESISTOR MUST BE USED ACROSS CONTACTS FOR DC OPERATION,NON-MAGNETIC S.S. CASE