NSN 5930-00-261-7964

Part Details | PRESSURE SWITCH

5930-00-261-7964 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Alternate Parts: ST5M1312001, ST5M1312-001, 8A819, 214C40132, 214C40-1-32, 1500P6, 5930-00-261-7964, 00-261-7964, 5930002617964, 002617964

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUL 15, 197300-261-796400206 ( SWITCH, PRESSURE )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-261-7964
Part Number Cage Code Manufacturer
ST5M1312-00176301BOEING COMPANY, THEDBA BOEING
8A81909049CUSTOM CONTROL SENSORS, LLCDBA CUSTOM AVIATION SUPPLY
214C40-1-3202750EATON AEROSPACE LLCDIV FLUID & ELECTRICAL DISTRIBUTION
1500P698087ITT AEROSPACE CONTROLS LLCDBA ITT AEROSPACE CONTROLS UNIT S
Technical Data | NSN 5930-00-261-7964
Characteristic Specifications
STYLE DESIGNATOR8 CYLINDRICAL W/FLANGE
OVERALL LENGTH3.600 INCHES MAXIMUM
BODY LENGTH2.000 INCHES MAXIMUM
OVERALL DIAMETER1.420 INCHES MAXIMUM
PRESSURE SWITCH TYPE ABSOLUTE
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUS DECREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATINGBC11.50 ACTUATION POINT NOMINAL AND BC12.50 DEACTUATION POINT NOMINAL AND BC1.00 DIFFERENTIAL POINT NOMINAL
OPERATING TEMP RATING-65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED GAS
PROOF PRESSURE28.00 POUNDS PER SQUARE INCH
TERMINAL TYPE CONNECTOR, RECEPTACLE
MOUNTING METHOD CLAMP
TEST DATA DOCUMENT81349-MILS9395 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
SENSING ELEMENT BURST PRESSURE48.00 POUNDS PER SQUARE INCH