NSN 5930-00-308-7399
Part Details | ROTARY SWITCH
5930-00-308-7399 A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).
Alternate Parts: G122402006, G122-402-006, 8M360124S, 8M36-01-2-4S, 8A36124S, 8A36-1-2-4S, 8A360124S, 8A36-01-2-4S, M3786130605, M3786/13-0605, MILS378613, MIL-S-3786/13, 5930-00-308-7399, 00-308-7399, 5930003087399, 003087399
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | OCT 28, 1973 | 00-308-7399 | 02134 ( SWITCH, ROTARY ) |
REFERENCE DRAWINGS & PICTURES
TAP, CIRCULAR, BUSHING MOUNT

Cross Reference | NSN 5930-00-308-7399
Part Number | Cage Code | Manufacturer |
---|---|---|
G122-402-006 | 0D0D0 | BAE SYSTEMS INFORMATION ANDELECTRONIC SYSTEMS INTEGRATION INC. |
8M36-01-2-4S | 81073 | GRAYHILL, INC |
8A36-1-2-4S | 81073 | GRAYHILL, INC |
8A36-01-2-4S | 81073 | GRAYHILL, INC |
M3786/13-0605 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-S-3786/13 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5930-00-308-7399
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | TAP, CIRCULAR, BUSHING MOUNT |
OVERALL LENGTH | 1.697 INCHES NOMINAL |
OVERALL DIAMETER | 0.670 INCHES MINIMUM AND 0.800 INCHES MAXIMUM |
INDIVIDUAL SECTION QUANTITY | 1 |
SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
TERMINAL TYPE | TAB, SOLDER LUG |
TEST DATA DOCUMENT | 81349-MIL-S-3786 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 81349-MIL--3786 TO 13 GOVERNMENT SPECIFICATION |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
OPERATING TEMP RANGE | -65.0 TO +85.0 DEG CELSIUS |