NSN 5930-00-362-0376
Part Details | THERMOSTATIC SWITCH
5930-00-362-0376 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 68B580153101, 68B580153-101, 150T2431, 150T243-1, 1500T3, C79221, C7922-1, 5930-00-362-0376, 00-362-0376, 5930003620376, 003620376
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | FEB 18, 1974 | 00-362-0376 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-362-0376
Part Number | Cage Code | Manufacturer |
---|---|---|
68B580153-101 | 76301 | BOEING COMPANY, THEDBA BOEING |
150T243-1 | 09049 | CUSTOM CONTROL SENSORS, LLCDBA CUSTOM AVIATION SUPPLY |
1500T3 | 98087 | ITT AEROSPACE CONTROLS LLCDBA ITT AEROSPACE CONTROLS UNIT S |
C7922-1 | 81755 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN AERONAUTICS |
Technical Data | NSN 5930-00-362-0376
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 3 CYLINDRICAL W/FLANGE |
OVERALL LENGTH | 4.780 INCHES NOMINAL |
WIDTH ACROSS FLATS | 1.000 INCHES NOMINAL |
BODY DIAMETER | 1.000 INCHES NOMINAL |
BODY LENGTH | 2.000 INCHES NOMINAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | AF210.00 ACTUATION POINT NOMINAL AND AF195.00 DEACTUATION POINT NOMINAL |
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 365.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | LIQUID |
TEMP SENSING ELEMENT TYPE | BULB |
BULB LENGTH | 1.065 INCHES NOMINAL |
BULB DIAMETER | 0.620 INCHES MAXIMUM |
TERMINAL TYPE | CONNECTOR, RECEPTACLE |
MOUNTING METHOD | THREADED BUSHING |
FEATURES PROVIDED | ELECTRICAL ACCESS PORT AND INTERNALLY GROUNDED |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERTIGHT |